What Size Generator To Run A 4 Ton AC Unit? Essential Sizing Guide For Homeowners And Businesses

Having the right generator to power a 4 ton air conditioner ensures both comfort and safety during power outages. Choosing an appropriately sized generator for a 4 ton AC unit requires considering wattage, voltage, starting and running loads, efficiency, and fuel types. This comprehensive guide demystifies generator sizing so you can make an informed, cost-effective purchase.

Factor Details for 4 Ton AC Unit
Typical Running Watts 4,800-6,000 Watts (20-25 Amps @ 240V)
Starting (Surge) Watts 14,000-18,000 Watts
Fuel Type Gasoline, Propane, Natural Gas, Diesel
Recommended Generator Size 17kW-22kW (Whole House/ Standby)
Portable Possible? Yes, but heavy-duty only (Tri-fuel, 12kW+)
Contents hide

Understanding 4 Ton AC Units And Power Requirements

What Does A 4 Ton AC Unit Mean?

A 4 ton AC unit is a central air conditioner capable of removing approximately 48,000 BTUs of heat per hour. In most American homes, a 4 ton AC is suited for large spaces ranging from 2,000 to 2,500 square feet.

The “ton” rating indicates cooling capacity, not weight. One ton equals 12,000 BTUs per hour, so a 4 ton unit is a high-capacity appliance requiring substantial electrical power, especially during compressor startup.

Typical Electrical Specs For A 4 Ton AC Unit

  • Voltage: 208-240V (Most often 240V in the U.S.)
  • Running Amperage: 20-25 Amps
  • Running Watts: 4,800-6,000W (Depends on SEER & efficiency)
  • Surge/Starting Amps: 70-110 Amps (5-7x running amps)

These numbers are crucial for generator sizing due to the much higher “inrush” of current when the compressor turns on.

Calculating Generator Size For A 4 Ton AC Unit

Understanding Running Vs. Starting Power Needs

Running watts represent the continual power your AC needs, while starting (surge) watts are required momentarily when the compressor initiates. The generator must handle both—especially the brief starting surge—without tripping or stalling.

  • Running Watts: Typically 4,800 to 6,000 watts for a 4 ton unit
  • Starting Watts: Can spike between 14,000 and 18,000 watts (sometimes higher on older models)

Formula For Generator Size

Minimum Generator Wattage = (Starting Amps x Voltage)
Example:

  • Starting amps: 80A
  • Voltage: 240V

Starting Load = 80A x 240V = 19,200W

Running Load = 25A x 240V = 6,000W

Generator should be capable of handling at least the surge (starting) wattage for seamless operation.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

Recommended Generator Size

  • Minimum Size For Only The 4 Ton AC: 17kW-22kW standby generator accommodates both surge and running loads, plus a small safety margin
  • For AC + Home Appliances: Opt for 22kW-30kW generator depending on overall household demand

Never size a generator strictly to the running watts—always include the starting surge.

Generator Types Suitable For 4 Ton AC Units

Standby Generators (Whole House)

Standby generators are the best option for most homes and businesses with large AC units. They are permanently installed, automatic, fueled by natural gas or propane, and can manage large electrical loads including ACs.

  • Capacity: 17kW-30kW+ available
  • Key Features: Automatic transfer switch, seamless power during outages, quiet operation
  • Best For: Homeowners wanting to run AC, furnace, lights, and other essentials

Portable Generators

Standard portable generators often can’t supply the high starting load of 4 ton AC units. However, heavy-duty portables (12kW-15kW) may suffice if a soft starter is installed (see below).

  • Tri-Fuel Options: Gasoline, propane, and natural gas flexibility
  • Mobility: Can be moved, but require proper transfer switch and suitable connection
  • Use Case: Temporary, short-term power; job sites; limited home circuits

Inverter Generators

While inverter technology offers cleaner power, most consumer-grade inverter generators cannot handle the large surge loads of a 4 ton AC unit. High-capacity commercial inverters are costly and rare.

How Soft Starters Can Reduce Generator Size Requirements

What Is A Soft Starter?

A soft starter reduces the inrush current when your AC’s compressor kicks on. This is achieved by gradually ramping up power, dramatically lowering the required starting wattage.

  • Reduces Surge Amps: By up to 50–70%
  • Extends Equipment Life: Less mechanical and electrical stress

How Soft Starters Affect Generator Choice

With a soft starter, a 4 ton AC unit might require a generator rated at about 8kW-12kW instead of 17kW-22kW. This makes high-end portable generators a viable option in some cases.

Installation should be done by a licensed HVAC technician or electrician to ensure safety and code compliance.

Fuel Types And Runtime Considerations

Generator Fuel Options

  • Natural Gas: Clean, unlimited supply if piped, best for standby units
  • Propane: Long shelf life, available in rural areas, dual-fuel common
  • Diesel: High energy density, used for commercial/industrial standby
  • Gasoline: Portable, but less shelf-stable and requires careful storage

Runtime And Sizing Fuel Tanks

Larger generators have higher fuel demand, especially when running ACs for extended periods. For standby systems, ensure your fuel source (tank size or utility line) supports necessary runtime.

  • 22kW natural gas generator: ~300 cubic feet per hour at full load
  • 22kW propane: ~3.5 gallons per hour at full load

Other Factors Affecting Generator Sizing

Additional Loads In The Home Or Business

Don’t forget all other appliances—fridge, lights, well pump, electronics—when sizing your generator.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

  • Determine Essential Loads: List wattages for all devices to be powered simultaneously
  • Add To AC Load: Total load determines final generator size

Voltage Dip And Power Quality

Large AC compressors cause voltage dips at startup. Undersized generators lead to brownouts, tripped breakers, and equipment damage. A margin above minimum rating ensures power quality and AC reliability.

Climate Considerations

Hotter, more humid climates require longer and more frequent AC runtime, increasing generator operating costs and wear.

Installation, Transfer Switch, And Safety Essentials

Transfer Switch Importance

A professionally installed transfer switch is mandatory to safely isolate generator and utility power, preventing dangerous backfeeding and simplifying transition during outages.

  • Automatic Transfer Switch (ATS): Standard with standby units
  • Manual Transfer Switch: Used with portable generators

Permits And Code Compliance

Generator installation typically requires local electrical permits and adherence to National Electrical Code (NEC) guidelines. Seek licensed contractors for safe connection and code approval.

Maintenance Tips

  • Test generator monthly
  • Change oil and filters per manufacturer schedule
  • Keep fuel fresh and tanks free of contaminants

Periodic maintenance ensures your generator is ready when needed.

Common Questions On Sizing A Generator For A 4 Ton AC Unit

Can A 10kW Generator Run My 4 Ton AC Unit?

Not reliably, unless a soft starter is installed and total home load is minimized. Even then, peak surge may still trip the generator.

What’s The Risk Of Sizing Too Small?

A generator that’s too small will not start your AC, may stall under load, or could even damage equipment. Always err on the side of slightly more capacity.

What Is The Most Popular Brand For 4 Ton AC Generator Install?

Generac, Kohler, Cummins, and Briggs & Stratton are top brands specializing in residential standby generators in the 17kW-22kW range.

Are There Energy Efficient AC Models That Lower Generator Size Needs?

Yes! High SEER-rated or inverter-based AC units have more gradual startups, reducing surge loads, but most still require robust backup generators in the 15kW+ range.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

Cost Considerations For Generators Sizing To 4 Ton AC Units

Generator Price Ranges

  • 17kW-22kW Standby Generators: $4,500-$8,000 (equipment only)
  • Professional Installation: $1,500-$4,000 (dependent on site & local labor)
  • Soft Starter Retrofit: $350-$700 plus installation

Total installed cost can range from $6,000 to $12,000 for a full system capable of running a 4 ton AC unit.

Fuel Costs

Natural gas and propane offer lower operating costs for continuous use compared to gasoline or diesel. Calculate expected runtime and fuel availability when planning your emergency power strategy.

Quick Reference Chart: Generator Sizing For Common AC Units

AC Unit Size Running Watts Starting Watts (Typical) Recommended Generator (No Soft Starter) With Soft Starter
2 Ton (24,000 BTU) 2,000-2,500W 5,500-7,000W 8kW+ 5.5kW+
3 Ton (36,000 BTU) 3,000-3,800W 10,000-12,000W 12kW+ 8.5kW+
4 Ton (48,000 BTU) 4,800-6,000W 14,000-18,000W 17-22kW+ 10-12kW+
5 Ton (60,000 BTU) 6,000-7,500W 18,000-22,000W 22-25kW+ 12-15kW+

Professional Sizing And Installation Recommendations

Why Consult With An Electrician Or HVAC Professional?

A certified professional can accurately assess your total power needs, recommend specific generator models, and ensure safe, code-compliant installation. Many generator suppliers offer site surveys to size systems for your home’s specific wiring, loads, and transfer switch options.

Summary Of Steps For Sizing A Generator:

  1. Verify AC unit specs (tonnage, running, starting amps)
  2. Calculate running and starting watts
  3. Add wattage for essential circuits/appliances
  4. Select a generator rated above the highest calculated surge watts
  5. Consider a soft starter for lower required generator size
  6. Choose fuel type based on availability and runtime needs
  7. Ensure a transfer switch and professional installation are included

Proper planning and sizing will protect your comfort, equipment, and investment the next time the lights go out.